BernardElectrics
  1. Home
  2. Services
  3. New Home Builds
REC 11743 Rough In To Fit Off Builders & Owner Builders

New Home ElectricalPackages

From temporary site supply through to the final fit off and your Certificate of Electrical Safety. We work to the plan and to the builder's program, so the next trade is never waiting on us.

New home electrical rough in by Bernard Electrics with cabling run through timber wall framing
One trade, one programTemp supply, rough in, board, fit off and certification handled by the same team from start to finish.

Quick Quote

Three fields. We come back with an upfront price for your new home builds.

Licensed REC 11743 Fully Insured Emergency & Same Day Free Quotes Homes & Business

What The Package Covers

Everything Between Bare Frame And Handover

A new home package is not a list of power points. It is a sequence, and every stage has to land in the right week or the trade behind you stops. This is what a Bernard Electrics package includes as standard.

01

Temporary builder's supply

Site power and safety switches set up so the frame, the chippies and the concrete crew have compliant power from day one.

02

Consumer mains and metering

Underground or overhead mains run in and terminated, meter box positioned and prepared, ready for the distributor.

03

Full rough in to plan

Every circuit run through frame before the plasterer arrives. Lighting, power, dedicated appliance circuits, exhaust fans and heating and cooling supplies.

04

Switchboard, single or three phase

A properly sized board with RCD protection on the circuits the Wiring Rules require it on, plus spare ways so the house can grow later.

05

Data, TV and comms rough in

Cat6 and TV runs pulled at the same time as the power, which is the only cheap time to do it.

06

Fit off and commissioning

Points, switches, lights, fans, oven and cooktop connections, exhausts and smoke alarms all fitted, labelled and tested.

07

Testing and certification

Every circuit tested and a Certificate of Electrical Safety issued for the prescribed work, which is what the building surveyor and your lender will want to see.

08

Defects and handover

One walk through with you or the builder, and anything on the list closed out before we call it finished.

Completed new home kitchen with integrated appliance circuits and concealed LED strip lighting

Fit off is the part people see. Rough in is the part that decides whether the house works.

Stage By Stage

Where We Sit In Your Build

Stage 01

Plan And Quote

Send us the plans and the electrical layout. You get a fixed scope and an upfront price, not a provisional sum that moves later.

Stage 02

Temporary Supply

Site power in early so the trades behind us are never working off a neighbour's lead.

Stage 03

Rough In

Booked against your frame inspection date. Cables run, boxes set, board position prepared, ready for plaster.

Stage 04

Fit Off

After paint and joinery. Points, switches, lights, fans, appliances and alarms all fitted and set.

Stage 05

Test And Certify

Full test, board labelled, Certificate of Electrical Safety issued and handed over.

Scope

Standard Versus The Extras People Ask For

The base package covers a compliant, working house. The second column is the work that is far cheaper now, while the walls are open, than it will ever be again.

Included as standard

  • Lighting and power circuits throughout, run to the electrical plan
  • Dedicated circuits for oven, cooktop, dishwasher and laundry
  • Hardwired, interconnected smoke alarms
  • Exhaust fans and heating and cooling supplies
  • Switchboard with RCD protection and labelled circuits
  • External lighting and weatherproof outdoor points
  • Full test, commissioning and Certificate of Electrical Safety

Worth doing while the walls are open

  • EV charger circuit run to the garage, even if the charger comes later
  • Three phase supply if you have a pool, workshop or heavy heating and cooling load
  • Alfresco, pool and landscape circuits stubbed out to the right positions
  • Cat6 data to every bedroom, the study and the TV wall
  • Smart home automation wiring and switch positions
  • Solar ready conduit from the roof space to the switchboard
  • Extra spare ways in the board so the next change is not a board swap

Who We Work With

Builders, Owner Builders And Developers

01

Volume and custom builders

We read the program, we book against your inspection dates, and we tell you early if a variation is going to move the rough in. No chasing, no surprises on the fit off week.

02

Owner builders

You get the same package and the same certification, plus someone who will explain the electrical plan in plain English before you sign off on it. Most owner builders under order points and over order downlights, and that is worth a conversation before rough in.

03

Townhouse and multi dwelling developments

Metering, sub mains and individual unit distribution boards set up so each dwelling is separately metered and separately protected from the start.

Our Work

New Builds On The Tools

Photos from Bernard Electrics jobs around Melbourne. No stock imagery, just the work.

New build electrical rough in with cabling run through timber wall framing
New build rough in
Townhouse electrical rough in with cable runs to the sub board position
Townhouse rough in
Underground consumer mains and service cables terminated in a pit
Consumer mains

Questions

New Build Electrical FAQ

Both. We run new home electrical packages for builders on a program, and we work directly with owner builders who are managing their own trades. Either way the scope is written down and priced upfront before we start.

Twice for the main work, plus the temporary supply at the start. Rough in happens once the frame is up and before the plasterer, and fit off happens after paint and joinery. We book both against your program dates rather than guessing.

Yes. Every circuit is tested and a Certificate of Electrical Safety is issued for the prescribed electrical work. That is what the building surveyor will be looking for, and it is included, not an extra.

Yes, and it is the cheapest way to do it. Running a dedicated circuit and conduit to the garage during rough in costs a fraction of chasing it in after the walls are closed. The charger itself can go on years later.

Not always. It depends on your total load. A large home with ducted heating and cooling, a pool, a workshop or a fast EV charger can justify it. We work out the maximum demand from your plans and tell you honestly whether single phase will carry the house.

Yes. Cat6 data, TV and comms are roughed in at the same time as the power circuits, which is the only cheap time to run them. Positions are set with you before we pull anything.

It depends on the size of the house, the number of circuits, single or three phase supply, and how far the mains have to run. Send us the plans and the electrical layout and we will give you a free, itemised quote with the scope written down.

Service Areas

Where We Build

Based in Doncaster East and working right across inner Melbourne, the bayside suburbs, the south east and the eastern suburbs.

Bayside

  • Brighton
  • Sandringham
  • Hampton
  • Beaumaris
  • Black Rock
  • Cheltenham
  • Highett
  • Mentone
  • Parkdale
  • Mordialloc
  • Aspendale
  • Edithvale
  • Chelsea
  • Bonbeach
  • Carrum
  • Elwood

Inner Melbourne

  • Carlton
  • Fitzroy
  • Collingwood
  • Abbotsford
  • Richmond
  • Cremorne
  • South Yarra
  • Prahran
  • Windsor
  • St Kilda
  • Albert Park
  • Port Melbourne
  • South Melbourne
  • Southbank

South East

  • Oakleigh
  • Clayton
  • Mulgrave
  • Springvale
  • Noble Park
  • Dandenong
  • Keysborough
  • Endeavour Hills

Eastern Suburbs

  • Doncaster East
  • Glen Waverley
  • Mount Waverley
  • Wheelers Hill
  • Rowville
  • Wantirna
  • Ferntree Gully
  • Boronia
  • Bayswater

Got Plans? Get A Fixed Price.

Send through the plans and the electrical layout and we will come back with an itemised quote and a scope you can hold us to.

Contact

Talk To Us About Your New Home Builds

Phone, text, email or the form. Whatever is easiest. Urgent jobs are always best by phone.

Send An Enquiry

Tell us what you need and we will come back with a free quote.

Free quotes, no obligation. For an emergency, call 0474 906 716 instead of using the form.

Call Now Free Quote